The LAUNCH X431 O2-2 Scope Box Oscilloscope is a cutting-edge add-on module designed to enhance your automotive diagnostic capabilities. Featuring a new design and upgraded hardware, this 4-channel, 100MHz oscilloscope integrates seamlessly with LAUNCH X-431 series scan tools, such as the PRO3S+ V5.0, PAD V, and PAD VII, via the O2-2 application. It excels at detecting high-level faults in electrical components like sensors, actuators, and circuits, delivering accurate and conclusive diagnostic results. With features like one-click waveform saving, 23 automatic measurements, and waveform math operations, the O2-2 Scope Box streamlines complex troubleshooting, saving you time and boosting efficiency in your workshop.
Core Oscilloscope Features
The O2-2 Scope Box offers powerful oscilloscope functionality, making it an essential tool for diagnosing intricate electrical issues with precision and ease.
- 4-Channel Design: Monitor up to four signals simultaneously, allowing comprehensive analysis of multiple components in a single test.
- 100MHz Bandwidth: Capture high-frequency signals with a bandwidth of 100MHz, ensuring accurate diagnostics for modern vehicle electronics.
- 1Gbps Sampling Rate: Achieve a maximum sampling rate of 1Gbps for single-channel tests, 500M/s for two channels, and 250M/s for multiple channels, providing detailed waveform data.
- 10M Buffer Memory: Store up to 10M of data across four channels, enabling extensive waveform recording for in-depth analysis.
- 8-Bit Vertical Resolution: Deliver precise measurements with 8-bit resolution and ±3% vertical accuracy for reliable signal representation.
- Input Impedance: Support 1MΩ ±1.5% input resistance for compatibility with a wide range of automotive sensors and circuits.
- Overload Protection: Protect the device with ±200V overload protection on single inputs, ensuring durability during testing.
Advanced Diagnostic Functions
Tackle complex electrical faults with the O2-2 Scope Box’s advanced diagnostic capabilities, designed to enhance the functionality of your X-431 scan tool.
- ECU Troubleshooting: Diagnose electronic control unit issues by analyzing high-resolution waveform data, pinpointing faults in sensors, actuators, and circuits.
- Waveform Recording and Playback: Record high-resolution waveform data for future analysis, allowing you to review and compare signals to identify intermittent issues.
- Multiple Automotive Tests: Perform tests on circuits, sensors, actuators, ignition systems, communication systems, and combination tests, covering a wide range of diagnostic needs.
- CANBus Decoding: Decode CAN and LIN signals for accurate analysis of vehicle communication networks, ensuring reliable diagnostics.
- Self-Calibration: Optimize the oscilloscope signal path with self-calibration, maximizing measurement accuracy for consistent results.
Waveform Management Tools
Simplify waveform analysis with intuitive tools that make capturing, saving, and reviewing data faster and more efficient.
- One-Click Waveform Saving: Save the current waveform with a single click in a specified format, ready for use as a reference channel in future tests.
- One-Click Preset Parameters: Save existing settings as waveform preset parameters with one click, allowing quick loading for similar tests without repeated setup.
- Quick Trigger Switching: Support edge and pulse width triggers with intuitive settings, enabling fast switching between trigger sources for simplified operation.
- Convenient Cursor Operation: Enable horizontal and vertical cursors with one click, drag them independently, and use cursor tracking via highlight touches, improving efficiency by over 80%.
- Cursor/Phase Ruler Adjustment: Automatically adjust cursors and phase scales when zooming in or out, maintaining consistent measurement ranges.
- Zoom In/Out Functionality: Use two-point touch to zoom waveforms horizontally or vertically, or drag to review precise details with ease.
Automotive Testing Capabilities
The O2-2 Scope Box supports a variety of preset automotive tests, providing specific parameters and connection methods for quick and accurate diagnostics.
- Preset Project Tests: Access preconfigured tests for circuits, sensors, actuators, ignition systems, communication systems, and combination tests, streamlining the diagnostic process.
- 23 Automatic Measurements: Display 23 measurement settings (e.g., voltage, frequency, duty cycle) on one screen, accessible with a light touch and supporting one-click clearing for ease of use.
- Waveform Math Operations: Perform addition, subtraction, multiplication, division, and Fast Fourier Transform (FFT) on two channel waveforms, enabling advanced signal analysis.
- Demo Mode: Preset sine waveforms to demonstrate common functions without connecting the oscilloscope, ideal for training or setup verification.
User Interface Enhancements
Experience a user-friendly interface designed to maximize efficiency and flexibility during diagnostics.
- Multi-Language Support: Choose from multiple languages for a personalized user experience, ensuring accessibility for technicians worldwide.
- Virtual Keyboard Input: Enter names and characters directly via a virtual keyboard, streamlining operations by up to 90% compared to traditional input methods.
- Customizable Settings: Save personal system settings as configuration files for quick access, tailoring the oscilloscope to your preferences.
- Online Help Documentation: Access online help for each test project, providing guidance and improving diagnostic accuracy (documentation to be compiled based on needs).
- Split-Screen Display: View multiple waveforms or settings simultaneously with split-screen functionality, enhancing multitasking capabilities.
- Online Firmware Upgrade: Update firmware online to ensure compatibility with the latest features and tablet resolutions, unlike the manual upgrades required for the O2-1.
Connectivity and Data Transfer
Stay connected and transfer data effortlessly with the O2-2 Scope Box’s versatile power and communication options.
- USB Data Transfer: Sync data to external devices like laptops or tablets via USB, enabling easy storage and analysis.
- Power Supply Options: Power the oscilloscope via USB (5V/1A) or DC IN port (12V/24V), with PAD VII series tablets supporting USB power supply for added convenience.
- Double-Clip Power Cable: Connect to the vehicle battery (red to positive, black to negative) for reliable power during diagnostics.
- USB Cable Connection: Link the oscilloscope to the diagnostic device using a USB cable (Type B to Type A) for seamless integration.
Supported Devices
The LAUNCH X431 O2-2 Scope Box is compatible with a range of X-431 series scan tools, enhancing their diagnostic capabilities through the O2-2 application.
- X431 PRO ELITE
- X431 Throttle
- X431 Pad II AE
- X431 Torque
- X431 Turbo
- X431 PRO3S+ V5.0
- X431 PAD V
- X431 PAD VII
- X431 IMMO Elite
- X431 IMMO PLUS
Technical Specifications
The O2-2 Scope Box is built for performance and reliability, offering advanced specifications for professional-grade diagnostics.
- Channels: 4
- Bandwidth: 100MHz
- Rising Time: 3.5ns (typical)
- Accuracy: ±3%
- Input Impedance: 1MΩ ±1.5%
- Input Type: Single-ended, BNC Connector
- Input Coupling: DC, AC
- Overload Protection: ±200V on single input
- Timebase Ranges: 1ns~1ks (1, 2, or 4 channels)
- Vertical Resolution: 8 bits
- Buffer Memory: 10M (for 4 channels)
- Power Interface: USB port (5V/1A), DC IN port (12V/24V)
- Data Exchange: USB
- Trigger Modes: Normal, Auto, Single SEQ
- Advanced Triggers: Edge, Pulse width
- Operating Temperature: 0℃~50℃
- Power Consumption: Approximately 7.5W
- Start Time: Approximately 16s
Comparison with O2-1 Scope Box
The O2-2 Scope Box offers significant upgrades over the O2-1, enhancing usability and performance for modern diagnostics.
- Multi-Touch Gestures: Supports two-point touch for zooming waveforms vertically or horizontally, unlike the O2-1.
- Online Help: Provides online help documentation for test projects, not available on the O2-1.
- Online Firmware Upgrade: Supports online upgrades, compared to manual upgrades on the O2-1.
- Demo Function: Includes a demo mode with preset sine waveforms, absent in the O2-1.
- Split-Screen Display: Offers split-screen functionality for multitasking, not supported by the O2-1.
- Sampling Rate Improvement: Achieves 500M/s for two channels, compared to 250M/s for more than one channel on the O2-1.
- Buffer Memory: Provides 10M storage depth, compared to 50M on the O2-1, optimized for faster processing.
Package List
- 1pc x Launch O2-2 main unit
- 4pcs x HT 30 test lines
- 1pc x HT25 secondary ignition pick-up line
- 1pc x battery clip cable
- 1pc x USB cable
- 2pcs x HT201 attenuator
- 20pcs x piercing needles
- 2 pairs x multimeter probes
- 2 pairs x crocodile clips
- 5pcs x colored 4 female probes
- 4pcs x clipper fuses (5*20mm)
- 2pcs x screw head
- 1pc x user manual
- 1pc x color label
- 1pc x packing list