LAUNCH X431 O2-2 Scope Box Oscilloscope Bidirectional ECU Coding For PRO3S+ PADV
Couldn't load pickup availability
Return policy
Our goal is for every customer to be totally satisfied with their purchase. If this isn't the case, let us know and we'll do our best to work with you to make it right.
Shipping
We will work quickly to ship your order as soon as possible. Once your order has shipped, you will receive an email with further information. Delivery times vary depending on your location.

LAUNCH X431 O2-2 Scope Box Oscilloscope
Product Overview
The LAUNCH X431 O2-2 Scope Box Oscilloscope is a cutting-edge add-on module designed to enhance your automotive diagnostic capabilities. Featuring a new design and upgraded hardware, this 4-channel, 100MHz oscilloscope integrates seamlessly with LAUNCH X-431 series scan tools, such as the PRO3S+ V5.0, PAD V, and PAD VII, via the O2-2 application. It excels at detecting high-level faults in electrical components like sensors, actuators, and circuits, delivering accurate and conclusive diagnostic results. With features like one-click waveform saving, 23 automatic measurements, and waveform math operations, the O2-2 Scope Box streamlines complex troubleshooting, saving you time and boosting efficiency in your workshop.
Core Oscilloscope Features
The O2-2 Scope Box offers powerful oscilloscope functionality, making it an essential tool for diagnosing intricate electrical issues with precision and ease.
- 4-Channel Design: Monitor up to four signals simultaneously, allowing comprehensive analysis of multiple components in a single test.
- 100MHz Bandwidth: Capture high-frequency signals with a bandwidth of 100MHz, ensuring accurate diagnostics for modern vehicle electronics.
- 1Gbps Sampling Rate: Achieve a maximum sampling rate of 1Gbps for single-channel tests, 500M/s for two channels, and 250M/s for multiple channels, providing detailed waveform data.
- 10M Buffer Memory: Store up to 10M of data across four channels, enabling extensive waveform recording for in-depth analysis.
- 8-Bit Vertical Resolution: Deliver precise measurements with 8-bit resolution and ±3% vertical accuracy for reliable signal representation.
- Input Impedance: Support 1MΩ ±1.5% input resistance for compatibility with a wide range of automotive sensors and circuits.
- Overload Protection: Protect the device with ±200V overload protection on single inputs, ensuring durability during testing.
Advanced Diagnostic Functions
Tackle complex electrical faults with the O2-2 Scope Box’s advanced diagnostic capabilities, designed to enhance the functionality of your X-431 scan tool.
- ECU Troubleshooting: Diagnose electronic control unit issues by analyzing high-resolution waveform data, pinpointing faults in sensors, actuators, and circuits.
- Waveform Recording and Playback: Record high-resolution waveform data for future analysis, allowing you to review and compare signals to identify intermittent issues.
- Multiple Automotive Tests: Perform tests on circuits, sensors, actuators, ignition systems, communication systems, and combination tests, covering a wide range of diagnostic needs.
- CANBus Decoding: Decode CAN and LIN signals for accurate analysis of vehicle communication networks, ensuring reliable diagnostics.
- Self-Calibration: Optimize the oscilloscope signal path with self-calibration, maximizing measurement accuracy for consistent results.
Waveform Management Tools
Simplify waveform analysis with intuitive tools that make capturing, saving, and reviewing data faster and more efficient.
- One-Click Waveform Saving: Save the current waveform with a single click in a specified format, ready for use as a reference channel in future tests.
- One-Click Preset Parameters: Save existing settings as waveform preset parameters with one click, allowing quick loading for similar tests without repeated setup.
- Quick Trigger Switching: Support edge and pulse width triggers with intuitive settings, enabling fast switching between trigger sources for simplified operation.
- Convenient Cursor Operation: Enable horizontal and vertical cursors with one click, drag them independently, and use cursor tracking via highlight touches, improving efficiency by over 80%.
- Cursor/Phase Ruler Adjustment: Automatically adjust cursors and phase scales when zooming in or out, maintaining consistent measurement ranges.
- Zoom In/Out Functionality: Use two-point touch to zoom waveforms horizontally or vertically, or drag to review precise details with ease.
Automotive Testing Capabilities
The O2-2 Scope Box supports a variety of preset automotive tests, providing specific parameters and connection methods for quick and accurate diagnostics.
- Preset Project Tests: Access preconfigured tests for circuits, sensors, actuators, ignition systems, communication systems, and combination tests, streamlining the diagnostic process.
- 23 Automatic Measurements: Display 23 measurement settings (e.g., voltage, frequency, duty cycle) on one screen, accessible with a light touch and supporting one-click clearing for ease of use.
- Waveform Math Operations: Perform addition, subtraction, multiplication, division, and Fast Fourier Transform (FFT) on two channel waveforms, enabling advanced signal analysis.
- Demo Mode: Preset sine waveforms to demonstrate common functions without connecting the oscilloscope, ideal for training or setup verification.
User Interface Enhancements
Experience a user-friendly interface designed to maximize efficiency and flexibility during diagnostics.
- Multi-Language Support: Choose from multiple languages for a personalized user experience, ensuring accessibility for technicians worldwide.
- Virtual Keyboard Input: Enter names and characters directly via a virtual keyboard, streamlining operations by up to 90% compared to traditional input methods.
- Customizable Settings: Save personal system settings as configuration files for quick access, tailoring the oscilloscope to your preferences.
- Online Help Documentation: Access online help for each test project, providing guidance and improving diagnostic accuracy (documentation to be compiled based on needs).
- Split-Screen Display: View multiple waveforms or settings simultaneously with split-screen functionality, enhancing multitasking capabilities.
- Online Firmware Upgrade: Update firmware online to ensure compatibility with the latest features and tablet resolutions, unlike the manual upgrades required for the O2-1.
Connectivity and Data Transfer
Stay connected and transfer data effortlessly with the O2-2 Scope Box’s versatile power and communication options.
- USB Data Transfer: Sync data to external devices like laptops or tablets via USB, enabling easy storage and analysis.
- Power Supply Options: Power the oscilloscope via USB (5V/1A) or DC IN port (12V/24V), with PAD VII series tablets supporting USB power supply for added convenience.
- Double-Clip Power Cable: Connect to the vehicle battery (red to positive, black to negative) for reliable power during diagnostics.
- USB Cable Connection: Link the oscilloscope to the diagnostic device using a USB cable (Type B to Type A) for seamless integration.
Supported Devices
The LAUNCH X431 O2-2 Scope Box is compatible with a range of X-431 series scan tools, enhancing their diagnostic capabilities through the O2-2 application.
- X431 PRO ELITE
- X431 Throttle
- X431 Pad II AE
- X431 Torque
- X431 Turbo
- X431 PRO3S+ V5.0
- X431 PAD V
- X431 PAD VII
- X431 IMMO Elite
- X431 IMMO PLUS
Technical Specifications
The O2-2 Scope Box is built for performance and reliability, offering advanced specifications for professional-grade diagnostics.
- Channels: 4
- Bandwidth: 100MHz
- Rising Time: 3.5ns (typical)
- Accuracy: ±3%
- Input Impedance: 1MΩ ±1.5%
- Input Type: Single-ended, BNC Connector
- Input Coupling: DC, AC
- Overload Protection: ±200V on single input
- Timebase Ranges: 1ns~1ks (1, 2, or 4 channels)
- Vertical Resolution: 8 bits
- Buffer Memory: 10M (for 4 channels)
- Power Interface: USB port (5V/1A), DC IN port (12V/24V)
- Data Exchange: USB
- Trigger Modes: Normal, Auto, Single SEQ
- Advanced Triggers: Edge, Pulse width
- Operating Temperature: 0℃~50℃
- Power Consumption: Approximately 7.5W
- Start Time: Approximately 16s
Comparison with O2-1 Scope Box
The O2-2 Scope Box offers significant upgrades over the O2-1, enhancing usability and performance for modern diagnostics.
- Multi-Touch Gestures: Supports two-point touch for zooming waveforms vertically or horizontally, unlike the O2-1.
- Online Help: Provides online help documentation for test projects, not available on the O2-1.
- Online Firmware Upgrade: Supports online upgrades, compared to manual upgrades on the O2-1.
- Demo Function: Includes a demo mode with preset sine waveforms, absent in the O2-1.
- Split-Screen Display: Offers split-screen functionality for multitasking, not supported by the O2-1.
- Sampling Rate Improvement: Achieves 500M/s for two channels, compared to 250M/s for more than one channel on the O2-1.
- Buffer Memory: Provides 10M storage depth, compared to 50M on the O2-1, optimized for faster processing.
Package List
- 1pc x Launch O2-2 main unit
- 4pcs x HT 30 test lines
- 1pc x HT25 secondary ignition pick-up line
- 1pc x battery clip cable
- 1pc x USB cable
- 2pcs x HT201 attenuator
- 20pcs x piercing needles
- 2 pairs x multimeter probes
- 2 pairs x crocodile clips
- 5pcs x colored 4 female probes
- 4pcs x clipper fuses (5*20mm)
- 2pcs x screw head
- 1pc x user manual
- 1pc x color label
- 1pc x packing list